Data Center Liquid Cooling 
· Ultra - reliable Leakage Prevention & Safety:
All key couplings undergo 100% helium leak testing, such as OCP UQDB universal quick - disconnect blind - mate couplings. Their self - aligning design can compensate for installation deviations, and the patented locking mechanism prevents accidental disconnection. Flame - retardant hoses (UL 94 V0 rating) reduce fire risks, which is critical for avoiding short circuits of electronic components caused by fluid leakage.
· Efficient Heat Transfer & Low Energy Consumption:
For cold plate systems, low - resistance EPDM hoses and large - flow couplings reduce pressure loss by over 20%, ensuring the heat transfer efficiency of water - glycol solutions. For immersion systems, hoses and pipe fittings with optimized inner wall smoothness are matched with low - viscosity fluids, reducing pumping energy consumption by 15 - 25% compared with conventional industrial pipelines.
· Strong Material Compatibility & Durability:
The conveyed fluids cover water - based solutions, synthetic hydrocarbons, and fluorinated fluids. The corresponding hoses and fittings are made of materials compatible with these media. For example, EPDM hoses resist corrosion from glycol, and special synthetic rubber hoses are compatible with ester - based fluids. They can withstand long - term circulation of different media without aging or cracking, with a service life of 10 - 15 years.
· Adaptability to Confined & Complex Spaces:
The kink - resistant hoses with small bending radii can be flexibly routed in dense server racks. Blind - mate couplings (e.g., OCP Open Rack V3 BM QC) realize non - visual connection between server blades and racks, adapting to the narrow operation space at the back of servers. Tool - free quick - connect structures simplify installation and maintenance in confined spaces.
· Compliance with Industry Standards & Environmental Norms:
The components comply with OCP (Open Compute Project) specifications, matching the interface standards of mainstream server brands. Fluorine - free fluid conveyance options meet global PFAS regulatory requirements. Biodegradable hoses and natural ester fluid matching solutions are in line with the ESG goals of data centers.
Data Center Liquid Cooling 
· Ultra - reliable Leakage Prevention & Safety:
All key couplings undergo 100% helium leak testing, such as OCP UQDB universal quick - disconnect blind - mate couplings. Their self - aligning design can compensate for installation deviations, and the patented locking mechanism prevents accidental disconnection. Flame - retardant hoses (UL 94 V0 rating) reduce fire risks, which is critical for avoiding short circuits of electronic components caused by fluid leakage.
· Efficient Heat Transfer & Low Energy Consumption:
For cold plate systems, low - resistance EPDM hoses and large - flow couplings reduce pressure loss by over 20%, ensuring the heat transfer efficiency of water - glycol solutions. For immersion systems, hoses and pipe fittings with optimized inner wall smoothness are matched with low - viscosity fluids, reducing pumping energy consumption by 15 - 25% compared with conventional industrial pipelines.
· Strong Material Compatibility & Durability:
The conveyed fluids cover water - based solutions, synthetic hydrocarbons, and fluorinated fluids. The corresponding hoses and fittings are made of materials compatible with these media. For example, EPDM hoses resist corrosion from glycol, and special synthetic rubber hoses are compatible with ester - based fluids. They can withstand long - term circulation of different media without aging or cracking, with a service life of 10 - 15 years.
· Adaptability to Confined & Complex Spaces:
The kink - resistant hoses with small bending radii can be flexibly routed in dense server racks. Blind - mate couplings (e.g., OCP Open Rack V3 BM QC) realize non - visual connection between server blades and racks, adapting to the narrow operation space at the back of servers. Tool - free quick - connect structures simplify installation and maintenance in confined spaces.
· Compliance with Industry Standards & Environmental Norms:
The components comply with OCP (Open Compute Project) specifications, matching the interface standards of mainstream server brands. Fluorine - free fluid conveyance options meet global PFAS regulatory requirements. Biodegradable hoses and natural ester fluid matching solutions are in line with the ESG goals of data centers.